Yuan Dongliang, Zhao Yaohua, Deng Haitao, et al. Application of self-made vacuum sealing drainage device in postoperative fixation and drainage of abdominal pedicled flaps in 8 patients with deep burns of upper limbs[J]. Chin j Burns, 2019, 35(8): 611-613. Doi: 10.3760/cma.j.issn.1009-2587.2019.08.011
Citation: Yuan Dongliang, Zhao Yaohua, Deng Haitao, et al. Application of self-made vacuum sealing drainage device in postoperative fixation and drainage of abdominal pedicled flaps in 8 patients with deep burns of upper limbs[J]. Chin j Burns, 2019, 35(8): 611-613. Doi: 10.3760/cma.j.issn.1009-2587.2019.08.011

Application of self-made vacuum sealing drainage device in postoperative fixation and drainage of abdominal pedicled flaps in 8 patients with deep burns of upper limbs

doi: 10.3760/cma.j.issn.1009-2587.2019.08.011
  • Received Date: 2018-04-26
    Available Online: 2021-10-28
  • Publish Date: 2019-08-20
  • From January 2013 to December 2017, 8 patients with deep burns of upper limbs were admitted to our hospital, including 6 males and 2 females, aged 23-48 years. The wound area of full-thickness burns to burns with tendon and bone injury was 4.5 cm×2.0 cm-20.0 cm×10.5 cm. After debridement, thin abdominal flaps with subdermal vascular network in the size of 5.0 cm×2.5 cm-22.0 cm×12.0 cm were applied to cover the wounds, and the donor sites were sutured directly by relaxation. The disposable suction tubes with holes cut on side walls were used as drainage tubes. The part of drainage tubes with holes were wrapped with nano-silver antimicrobial dressings and then placed at the lowest position of pedicle and donor site of abdominal flap and the space between the injured limb and the abdominal wall. The loose nano-silver antibacterial dressing was used to fill the webs of fingers and the gap between the injured limb and the abdominal wall. The transparent film dressing was used to close the surgical area and then connected with a low negative voltage electric suction device to continuously suck at a negative pressure of -15 to -10 kPa. The self-made vacuum sealing drainage device was replaced at intervals of 4 to 5 days until pedicle breakage was performed 2 to 3 weeks after operation. The pedicled abdominal flaps of 8 patients had no torsion or avulsion, no pedicle blood supply disorder, and no infection or skin erosion in the operation area, and all the flaps survived after pedicle breakage.

     

  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (109) PDF downloads(6) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return