Volume 39 Issue 6
Jun.  2023
Turn off MathJax
Article Contents
Wang ZH,Fan JS,Mi YY,et al.Summary of best evidence for pulse contour cardiac output monitoring in severe burn patients[J].Chin J Burns Wounds,2023,39(6):573-580.DOI: 10.3760/cma.j.cn501225-20220825-00363.
Citation: Wang ZH,Fan JS,Mi YY,et al.Summary of best evidence for pulse contour cardiac output monitoring in severe burn patients[J].Chin J Burns Wounds,2023,39(6):573-580.DOI: 10.3760/cma.j.cn501225-20220825-00363.

Summary of best evidence for pulse contour cardiac output monitoring in severe burn patients

doi: 10.3760/cma.j.cn501225-20220825-00363
Funds:

Military Nursing Innovation and Cultivation Special Program 2021HL005

Incubation Project of Military Medical Science and Technology Youth Cultivation Program 20QNPY005

General Program of Natural Science Foundation of Chongqing cstc2020jcyj-msxmX1055

More Information
  • Corresponding author: Li Ning, Email: 335405006@qq.com
  • Received Date: 2022-08-25
  •   Objective   To summarize the best evidence for pulse contour cardiac output (PiCCO) monitoring in severe burn patients.   Methods   A bibliometric approach was used. Foreign language databases including UpToDate, BMJ Best Practice, Joanna Briggs Institute Evidence-Based Practice Database, Cochrane Library, PubMed, Web of Science, Embase, Medline, and Guideline International Network, as well as Chinese databases such as China National Knowledge Infrastructure, Wanfang Database, and VIP Database were systematically retrieved to obtain all the publicly published evidence on PiCCO monitoring in severe burn patients in each database from the establishment of each database to May 2022, including guidelines, expert consensus, evidence summary, systematic review, and original research. The literature was screened and evaluated for the quality, from which the evidences were extracted, evaluated, and classified to summarize the best evidences.   Results   Three guidelines, two expert consensuses, one evidence summary (with two systematic reviews being traced), two systematic reviews, three randomized controlled trials, one cohort study, and one case-control study were retrieved and included, with good quality of literature. Totally 37 pieces of best evidences about PiCCO monitoring in severe burn patients were summarized from the aspects of pre-operation evaluation, pipe placement and operation, monitoring system establishment, pipeline maintenance, and supervision and education.   Conclusions   Totally 37 pieces of best evidences about PiCCO monitoring in severe burn patients are summarized from 5 aspects, providing a basis for the clinical implementation of scientific and standardized PiCCO monitoring and nursing management.

     

  • loading
  • [1]
    TianH,WangL,XieW,et al.Epidemiologic and clinical characteristics of severe burn patients: results of a retrospective multicenter study in China, 2011-2015[J/OL].Burns Trauma,2018,6:14[2022-08-25].https://pubmed.80599.net/29850643/.DOI: 10.1186/s41038-018-0118-z.
    [2]
    ChenSL,LanFC,DuZS,et al.Influence of injection rates of calibrating standard solution on monitoring pulse indicator continuous cardiac output[J].Biomed Eng Online,2018,17(1):34.DOI: 10.1186/s12938-018-0453-0.
    [3]
    LittonE,MorganM.The PiCCO monitor: a review[J].Anaesth Intensive Care,2012,40(3):393-409.DOI: 10.1177/0310057X1204000304.
    [4]
    蒋南红,王德运,李凤,等.脉搏轮廓心排血量监测技术指导大面积烧伤休克期补液的临床意义[J].中华烧伤杂志,2019,35(6):434-440.DOI: 10.3760/cma.j.issn.1009-2587.2019.06.007.
    [5]
    中国老年医学学会烧创伤分会.脉搏轮廓心排血量监测技术在严重烧伤治疗中应用的全国专家共识(2018版)[J].中华烧伤杂志,2018,34(11):776-781.DOI: 10.3760/cma.j.issn.1009-2587.2018.11.011.
    [6]
    李一,周军利.脉搏轮廓心排血量监测技术在大面积烧伤患者中的应用研究进展[J].中华烧伤杂志,2018,34(10):737-740.DOI: 10.3760/cma.j.issn.1009-2587.2018.10.018.
    [7]
    陈丽映,胡蓉丽,余惠,等.特重度烧伤合并肌红蛋白尿性急性肾功能衰竭患者应用PICCO技术1例的护理[J].护理与康复,2018,17(2):97-99.DOI: 10.3969/j.issn.1671-9875.2018.02.036.
    [8]
    崔立军,鲍勇,陈昕,等.中国康复临床实践指南的质量评价[J].中国循证医学杂志,2019,19(6):723-728.DOI: 10.7507/1672-2531.201806079.
    [9]
    AromatarisE,SternC,LockwoodC,et al.JBI series paper 2: tailored evidence synthesis approaches are required to answer diverse questions: a pragmatic evidence synthesis toolkit from JBI[J].J Clin Epidemiol,2022,150:196-202.DOI: 10.1016/j.jclinepi.2022.04.006.
    [10]
    刘辉,苏仁凤,石安娅,等.中国科学引文数据库收录期刊的系统评价/Meta分析文献方法学质量评价[J].协和医学杂志,2023,14(2):390-398.DOI: 10.12290/xhyxzz.2022-0317.
    [11]
    卢福长,沈鸣雁,沈涛,等.成人重度烧伤术后低体温复温的证据总结[J].中华烧伤杂志,2020,36(7):582-586.DOI: 10.3760/cma.j.cn501120-20190402-00158.
    [12]
    王轶,韩柳,袁翠,等.成人ICU患者外周动脉导管留置与维护的最佳证据总结[J].中华护理杂志,2020,55(4):600-606.DOI: 10.3761/j.issn.0254-1769.2020.04.023.
    [13]
    ISBI Practice Guidelines Committee,SubcommitteeSteering,SubcommitteeAdvisory.ISBI Practice Guidelines for Burn Care[J].Burns,2016,42(5):953-1021.DOI: 10.1016/j.burns.2016.05.013.
    [14]
    ISBI Practice Guidelines Committee,SubcommitteeAdvisory,SubcommitteeSteering.ISBI Practice Guidelines for Burn Care, Part 2[J].Burns,2018,44(7):1617-1706.DOI: 10.1016/j.burns.2018.09.012.
    [15]
    SasakiJ,MatsushimaA,IkedaH,et al.Japanese Society for Burn Injuries (JSBI) clinical practice guidelines for management of burn care (3rd edition)[J].Acute Med Surg,2022,9(1):e739.DOI: 10.1002/ams2.739.
    [16]
    中华医学会烧伤外科学分会.严重烧伤患者深静脉置管操作和管理的全国专家共识(2020版)[J].中华烧伤杂志,2021,37(2):101-112.DOI: 10.3760/cma.j.cn501120-20201122-00487.
    [17]
    SchlöglhoferT,GillyH,SchimaH.Semi-invasive measurement of cardiac output based on pulse contour: a review and analysis[J].Can J Anaesth,2014,61(5):452-479.DOI: 10.1007/s12630-014-0135-8.
    [18]
    WangB,CaiL,LinB,et al.Effect of pulse indicator continuous cardiac output monitoring on septic shock patients: a meta-analysis[J].Comput Math Methods Med,2022,2022:8604322.DOI: 10.1155/2022/8604322.
    [19]
    AboelattaY,AbdelsalamA.Volume overload of fluid resuscitation in acutely burned patients using transpulmonary thermodilution technique[J].J Burn Care Res,2013,34(3):349-354.DOI: 10.1097/BCR.0b013e3182642b32.
    [20]
    冯可,景福琴,李晓蕊,等.脉搏指示连续心排血量监测技术在大面积烧伤患者中的应用效果及护理[J].中国实用护理杂志,2019,35(6):421-425.DOI: 10.3760/cma.j.issn.1672-7088.2019.06.005.
    [21]
    NiX,LiuXJ,DingTT.The application of PiCCO-guided fluid resuscitation in patients with traumatic shock[J].Am Surg,2022:31348221087898.DOI: 10.1177/00031348221087898.
    [22]
    陈丽映,余惠,朱飘飘,等.PICCO技术对大面积烧伤患者休克期液体复苏中的应用[J].国际医药卫生导报,2020,26(13):1842-1845.DOI: 10.3760/cma.j.issn.1007-1245.2020.13.007.
    [23]
    GongC,ZhangF,LiL,et al.The variation of hemodynamic parameters through PiCCO in the early stage after severe burns[J].J Burn Care Res,2017,38(6):e966-e972.DOI: 10.1097/BCR.0000000000000533.
    [24]
    GuWJ,WuXD,WangF,et al.Ultrasound guidance facilitates radial artery catheterization: a meta-analysis with trial sequential analysis of randomized controlled trials[J].Chest,2016,149(1):166-179.DOI: 10.1378/chest.15-1784.
    [25]
    Robertson-MaltS,MaltGN,FarquharV,et al.Heparin versus normal saline for patency of arterial lines[J].Cochrane Database Syst Rev,2014,2014(5):CD007364.DOI: 10.1002/14651858.CD007364.pub2.
    [26]
    SoltanyA,HasanAR,MohannaF.Burn management during the COVID-19 pandemic: recommendations and considerations[J].Avicenna J Med,2020,10(4):163-173.DOI: 10.4103/ajm.ajm_153_20.
    [27]
    MehtaR,traineeGP,ChinthapalliK,et al.Glasgow coma scale explained[J].BMJ,2019,365:l1296.DOI: 10.1136/bmj.l1296.
    [28]
    SchmidtS,WesthoffTH,HofmannC,et al.Effect of the venous catheter site on transpulmonary thermodilution measurement variables[J].Crit Care Med,2007,35(3):783-786.DOI: 10.1097/01.CCM.0000256720.11360.FB.
    [29]
    GreenhalghDG,SaffleJR,4thHolmes JH,et al.American Burn Association consensus conference to define sepsis and infection in burns[J].J Burn Care Res,2007,28(6):776-790.DOI: 10.1097/BCR.0b013e3181599bc9.
    [30]
    NorburyW,HerndonDN,TanksleyJ,et al.Infection in burns[J].Surg Infect (Larchmt),2016,17(2):250-255.DOI: 10.1089/sur.2013.134.
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Figures(1)  / Tables(4)

    Article Metrics

    Article views (258) PDF downloads(42) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return